Difference between revisions of "Gas Handling Equipment"
From Ug11bm
Jump to navigationJump to searchLine 1: | Line 1: | ||
== Gas Cylinders == | == Gas Cylinders == | ||
11-BM typically has standard gas cylinders available ( | 11-BM typically has standard gas cylinders available, such as: O2, N2, He, Air, and 3.5% H2 (He balance). But always check with beamline staff in advance to ensure gas availability for an experiment. Custom gas cylinders need to be requested well in advance. | ||
== Gas Regulators == | == Gas Regulators == | ||
11-BM has several dedicated high-purity gas regulators, including (as of Jan 2012): | 11-BM has several dedicated high-purity gas regulators, including (as of Jan 2012): | ||
* CGA Size #350, Dual-Stage, | * CGA Size #350, Dual-Stage, < 200 psi. Used with Carbon Monoxide, Hydrogen, Ethane, Ethylene, Methane, and related gases. ''(Sigma-Aldrich Part Z405973; mfr Matheson #3122-350)'' | ||
* CGA Size #540, Dual-Stage, < 60 psi. Used with Oxygen. ''(Sigma-Aldrich Part Z405957; mfr Matheson #3121-540)'' | |||
* CGA Size #580, Dual-Stage, < 100 psi. Used with Inert Gases ''(multiple)'' | |||
* CGA Size #580, Dual-Stage, < 400 psi. Used with Inert Gases ''(Sigma-Aldrich Part Z405922; mfr. no. Matheson #3126-580)'' | |||
== Hutch Patch Panel == | == Hutch Patch Panel == | ||
[[Image:HutchPatchPanel.png|frameless|600px|Hutch Patch Panel]] | [[Image:HutchPatchPanel.png|frameless|600px|Hutch Patch Panel Image (soon!)]] |
Revision as of 22:27, 3 January 2012
Gas Cylinders
11-BM typically has standard gas cylinders available, such as: O2, N2, He, Air, and 3.5% H2 (He balance). But always check with beamline staff in advance to ensure gas availability for an experiment. Custom gas cylinders need to be requested well in advance.
Gas Regulators
11-BM has several dedicated high-purity gas regulators, including (as of Jan 2012):
- CGA Size #350, Dual-Stage, < 200 psi. Used with Carbon Monoxide, Hydrogen, Ethane, Ethylene, Methane, and related gases. (Sigma-Aldrich Part Z405973; mfr Matheson #3122-350)
- CGA Size #540, Dual-Stage, < 60 psi. Used with Oxygen. (Sigma-Aldrich Part Z405957; mfr Matheson #3121-540)
- CGA Size #580, Dual-Stage, < 100 psi. Used with Inert Gases (multiple)
- CGA Size #580, Dual-Stage, < 400 psi. Used with Inert Gases (Sigma-Aldrich Part Z405922; mfr. no. Matheson #3126-580)