Difference between revisions of "X-ray absorption & fluorescence"
From Ug11bm
Jump to navigationJump to searchLine 27: | Line 27: | ||
== Links == | == Links == | ||
'''WebAbsorb''': web based calculator to compute X-ray absorption for powder XRD capillary samples (11BM page) | |||
http://11bm.xor.aps.anl.gov/absorb/absorb.php | |||
https://subversion.xor.aps.anl.gov/trac/pyFprime/ | |||
* [http://csrri.iit.edu/mucal.html '''MuCal''': calculate X-ray absorption, fluorescence and more (by C. Segre @ IIT/ANL)] | * [http://csrri.iit.edu/mucal.html '''MuCal''': calculate X-ray absorption, fluorescence and more (by C. Segre @ IIT/ANL)] |
Revision as of 00:05, 29 August 2011
X-ray Absorption Information (11BM page) http://11bm.xor.aps.anl.gov/absorption.html
Absorption Length
The X-ray beam intensity (of wavelength = Lambda) at depth x into a material is calculated by Beer-Lambert law:
I(x) = e^(-x/Lambda)
The Absorption Length is then defined as the distance into a material where the x-ray beam intensity has decreased to 1 / e, or about 63%. (alternatively called Attenuation Length). Recall that e = 2.718.
This is a convenient value because:
(1/e) = e^(-x/Lambda) ln(1/e) = ln(e ^-x/Lambda) 1 = x/Lambda x = 1/Lambda
and
x = 1/mu
Links
WebAbsorb: web based calculator to compute X-ray absorption for powder XRD capillary samples (11BM page) http://11bm.xor.aps.anl.gov/absorb/absorb.php
https://subversion.xor.aps.anl.gov/trac/pyFprime/