Difference between revisions of "Standards Data"
Line 40: | Line 40: | ||
===11-BM background, air scatter only (no sample)=== | ===11-BM background, air scatter only (no sample)=== | ||
''Note: exact background shape for 2θ < 2° may vary. Contact 11-BM staff | ''Note: exact background shape for 2θ < 2° may vary due to beamstop positioning. Contact 11-BM staff with questions.'' | ||
*[http://11bm.xray.aps.anl.gov/data/standards/background/11BM_background_air_scatter.jpg Background Air Scatter (jpg)] | *[http://11bm.xray.aps.anl.gov/data/standards/background/11BM_background_air_scatter.jpg Background Air Scatter (jpg)] | ||
*[http://11bm.xray.aps.anl.gov/data/standards/background/11BM_background_air_scatter.fxye GSAS .fxye format] | *[http://11bm.xray.aps.anl.gov/data/standards/background/11BM_background_air_scatter.fxye GSAS .fxye format] |
Revision as of 23:11, 10 May 2013
!! Wiki page below is under construction !!!
see 11BM webpage for more info: http://11bm.xor.aps.anl.gov/standards_data.html
Standard Reference Materials
Details of powder diffraction data measured at 11-BM for standard reference materials are listed below and are available in several formats. These are periodically updated. Contact 11-BM staff with questions.
Data are typically measured at ~ 30 keV under ambient conditions. Check the file header for full details and scan parameters.
More information about 11-BM data collection and data formats can be found here:
NIST SRM Certificates (with lattice values etc) are available for download here:
Lanthanum Hexaboride (LaB6), NIST SRM 660a
- LaB6 660a Plot (jpg)
- GSAS .fxye format
- GSAS .raw format
- TOPAS .xye format
- ASCII .csv format
- Fullprof .xy format
Silicon (Si), NIST SRM 640c
- Si 640c Plot (jpg)
- GSAS .fxye format
- GSAS .raw format
- TOPAS .xye format
- ASCII .csv format
- Fullprof .xy format
Empty 11-BM Kapton sample capillary
- Empty Kapton Plot (jpg)
- GSAS .fxye format
- GSAS .raw format
- TOPAS .xye format
- ASCII .csv format
- Fullprof .xy format
11-BM background, air scatter only (no sample)
Note: exact background shape for 2θ < 2° may vary due to beamstop positioning. Contact 11-BM staff with questions.
- Background Air Scatter (jpg)
- GSAS .fxye format
- GSAS .raw format
- TOPAS .xye format
- ASCII .csv format
- Fullprof .xy format
NAC
coming soon
Example instrument parameter & input files for GSAS, Topas, and FullProf »
Plot of background for empty 11-BM 0.8 mm Kapton capillary (@ 30 KeV)
http://11bm.xor.aps.anl.gov/data/standards/Kapton/2010_1/11BM_Kapton.jpg
Plot of empty background (no sample or capillary)for 11-BM, air scatter only (@ 30 KeV)
http://11bm.xor.aps.anl.gov/data/standards/background/11BM_background_air_scatter.jpg