==Overview==
11-BM High-Resolution Powder Diffraction Mail-In Instructions:
Carefully read these instructions to ensure a successful mail-in experiment.
Please contact beamline staff ([email protected]) with questions or comments at any time.
SAMPLE BASE KIT:
The requested mail-in sample base kit(s) and pre-printed return-shipping label are enclosed.
Each sample kit contains the following:
Mounting Base: a unique barcode number (e.g. ANL0AA1234) printed on the side & bottom (as a 2D barcode). This number is needed to register samples, and is used to track the sample in all steps of the mail-in service. Do not use solvents to clean the base; this will damage the printed barcode and number.
Magnetic Cap: to cover and protect samples during shipment & handling. Do not write on the caps; they are re-used and cannot be used to identify your sample. All samples must fit completely inside the caps; the 11-BM robotic sample loader will destroy longer samples. 
Kapton Capillary Tubes: to contain samples. The inner diameter of the supplied tube is 0.80 mm. The outside diameter fits snugly inside the mounting base.  All samples (powders, foils, nested capillaries, etc.) must be fully contained and secured within straight Kapton tubes.  Samples are spun at high speed during data collection.  Non-secured samples will shift or move out of the beam position when spun. We cannot mount unsecured or bend samples. Kapton tubes are provided for your convenience. Kapton is stable over a wide temperature range and adds a negligible contribution to the diffraction scan background.

Revision as of 16:45, 9 October 2012

wiki page under construction,

see http://11bm.xray.aps.anl.gov/instructions.html




Overview

11-BM High-Resolution Powder Diffraction Mail-In Instructions:

Carefully read these instructions to ensure a successful mail-in experiment. Please contact beamline staff ([email protected]) with questions or comments at any time.

SAMPLE BASE KIT: The requested mail-in sample base kit(s) and pre-printed return-shipping label are enclosed. Each sample kit contains the following:

Mounting Base: a unique barcode number (e.g. ANL0AA1234) printed on the side & bottom (as a 2D barcode). This number is needed to register samples, and is used to track the sample in all steps of the mail-in service. Do not use solvents to clean the base; this will damage the printed barcode and number.

Magnetic Cap: to cover and protect samples during shipment & handling. Do not write on the caps; they are re-used and cannot be used to identify your sample. All samples must fit completely inside the caps; the 11-BM robotic sample loader will destroy longer samples.

Kapton Capillary Tubes: to contain samples. The inner diameter of the supplied tube is 0.80 mm. The outside diameter fits snugly inside the mounting base. All samples (powders, foils, nested capillaries, etc.) must be fully contained and secured within straight Kapton tubes. Samples are spun at high speed during data collection. Non-secured samples will shift or move out of the beam position when spun. We cannot mount unsecured or bend samples. Kapton tubes are provided for your convenience. Kapton is stable over a wide temperature range and adds a negligible contribution to the diffraction scan background.