Difference between revisions of "Gas Handling Equipment"
From Ug11bm
Jump to navigationJump to searchLine 12: | Line 12: | ||
11-BM has several dedicated high-purity gas regulators, including (as of Jan 2012): | 11-BM has several dedicated high-purity gas regulators, including (as of Jan 2012): | ||
* CGA Size #350, Dual-Stage, Gauge < 200 psi ''(4-100 psig delivery) | For Carbon Monoxide, Hydrogen, Ethane, Ethylene, Methane, and related gases: | ||
*CGA Size #350, Dual-Stage, Gauge < 200 psi ''(4-100 psig delivery) (Sigma-Aldrich Part Z405973; mfr Matheson #3122-350)'' | |||
*CGA Size #540, Dual-Stage, Gauge < 60 psi ''(4-100 psig delivery) | For Oxygen: | ||
*CGA Size #540, Dual-Stage, Gauge < 60 psi ''(4-100 psig delivery) (Sigma-Aldrich Part Z405957; mfr Matheson #3121-540)'' | |||
*CGA Size #580, Dual-Stage, Gauge < 60 psi ''(2-30 psig delivery) | For Inert Gases: | ||
*CGA Size #580, Dual-Stage, Gauge < 60 psi ''(2-30 psig delivery) (Sigma-Aldrich Part Z405906; mfr. no. Matheson #3121-580)'' | |||
*CGA Size #580, Dual-Stage, Gauge < 100 psi. | *CGA Size #580, Dual-Stage, Gauge < 100 psi. ''(multiple regulators)'' | ||
*CGA Size #580, Dual-Stage, Gauge < 400 psi ''(10-250 psig delivery) (Sigma-Aldrich Part Z405922; mfr. no. Matheson #3126-580)'' | |||
*CGA Size #580, Dual-Stage, Gauge < 400 psi ''(10-250 psig delivery) | |||
Revision as of 22:38, 3 January 2012
Gas Cylinders
11-BM has standard gas cylinders available, typically:
- O2
- Inert Gases: N2, He, Air
- 3.5% H2 (He balance)
Always check with beamline staff in advance to ensure gas availability for an experiment. Custom gas cylinders need to be requested well in advance.
Gas Regulators
11-BM has several dedicated high-purity gas regulators, including (as of Jan 2012):
For Carbon Monoxide, Hydrogen, Ethane, Ethylene, Methane, and related gases:
- CGA Size #350, Dual-Stage, Gauge < 200 psi (4-100 psig delivery) (Sigma-Aldrich Part Z405973; mfr Matheson #3122-350)
For Oxygen:
- CGA Size #540, Dual-Stage, Gauge < 60 psi (4-100 psig delivery) (Sigma-Aldrich Part Z405957; mfr Matheson #3121-540)
For Inert Gases:
- CGA Size #580, Dual-Stage, Gauge < 60 psi (2-30 psig delivery) (Sigma-Aldrich Part Z405906; mfr. no. Matheson #3121-580)
- CGA Size #580, Dual-Stage, Gauge < 100 psi. (multiple regulators)
- CGA Size #580, Dual-Stage, Gauge < 400 psi (10-250 psig delivery) (Sigma-Aldrich Part Z405922; mfr. no. Matheson #3126-580)