Difference between revisions of "34ID Beamline Layout"
(→34ID-A) |
m (→34ID-A) |
||
Line 31: | Line 31: | ||
* Two sets of white-beam slits, one for each x-ray beam | * Two sets of white-beam slits, one for each x-ray beam | ||
* A few Bremsstrahlung Collimators | * A few Bremsstrahlung Collimators | ||
* A white-beam deflection mirror that further deflects the 34ID-C beam in the outboard direction. This mirror would provide enough separation between the two x-ray beams at the C-station so experiments can be performed there without too much spatial constraints | * A white-beam deflection mirror that further deflects the 34ID-C beam by 5 mrad in the outboard direction. This mirror would provide enough separation between the two x-ray beams at the C-station so experiments can be performed there without too much spatial constraints | ||
* A white-beam mask/stop for the outboard deflected/transmitted beam | * A white-beam mask/stop for the outboard deflected/transmitted beam | ||
Revision as of 22:47, 22 August 2013
(This article/section is incomplete, please check back again or help expanding it) |
↑ top view | ||||||
Storage Ring Tunnel Wall — ♦ | 34ID-A (FOE) | Beam transport | 34ID-B (SOE) | 34ID-C | 34ID-D (TOE) | 34ID-E |
↓ side view | ||||||
Sector 34ID has two undulator sources and five x-ray enclosures (also called hutches or stations): the first optical enclosure (FOE) 34ID-A, the second optical enclosure (SOE) 34ID-B, the coherent diffraction imaging experiment station 34ID-C, the third optical enclosure (TOE) 34ID-D, and the micro-diffraction station 34ID-E.
Undulator Sources
34ID has two undulators, positioned in tandem along a 5-meter straight section along the ring. Their horizontal directions are separated by 1 μrad. The upstream undulator produces the outboard beam, which eventually goes to 34ID-C for coherent diffraction imaging experiments. The downstream undulator produces the inboard beam that serves micro-diffraction at the E-hutch.
34ID-A
The first optical enclosure has the following components:
- Front-end exit mask, window, and collimator
- Two sets of white-beam slits, one for each x-ray beam
- A few Bremsstrahlung Collimators
- A white-beam deflection mirror that further deflects the 34ID-C beam by 5 mrad in the outboard direction. This mirror would provide enough separation between the two x-ray beams at the C-station so experiments can be performed there without too much spatial constraints
- A white-beam mask/stop for the outboard deflected/transmitted beam