Difference between revisions of "34-ID-C"

From 34-ID-C
Jump to navigationJump to search
Line 16: Line 16:
'''Linkam Cryo stage'''
'''Linkam Cryo stage'''


The guts of this cell is a Linkam THMS controller.  Temperatures as low as -100 C are possible but since the 3D printed chamber is not vacuum compatible, icing can be significant.  Development of a highly dried gas environment is underway to minimize icing.  The cell can also support moderate heating, limited by melting the 3D printed chamber.  We have maintained 50 C for many hours with no problem.  A newer version of the chamber, than that pictured, includes a magnetically secured removable cover.
The guts of this cell is a Linkam THMS controller.  Temperatures as low as -100 C are possible but since the 3D printed chamber is not vacuum compatible, icing can be significant.  Development of a highly dried gas environment is underway to minimize icing.  The cell can also support moderate heating, limited by melting the 3D printed chamber.  We have maintained 50 C for many hours with no problem.  A newer version of the chamber includes a magnetically secured removable cover.


[[File:Linkam1.JPG|320px]]  [[File:Linkam2.jpg|240px]]
[[File:Linkam1.JPG|320px]]  [[File:Linkam2.jpg|240px]]

Revision as of 21:45, 24 February 2018

Setup Images and Drawings

Media: 34IDC_basic_instrument_diagrams_for_mounting_assistance_etc.pdf

Sample Environments (Resident at beamline)

Heater Cell

The heater cell is capable of several hundred degrees centigrade. Improvements are underway to reach up to 1000 C. It also supports gas flow through the chamber. It is not vacuum compatible.

Heater1.jpg Heater2.jpg



Linkam Cryo stage

The guts of this cell is a Linkam THMS controller. Temperatures as low as -100 C are possible but since the 3D printed chamber is not vacuum compatible, icing can be significant. Development of a highly dried gas environment is underway to minimize icing. The cell can also support moderate heating, limited by melting the 3D printed chamber. We have maintained 50 C for many hours with no problem. A newer version of the chamber includes a magnetically secured removable cover.

Linkam1.JPG Linkam2.jpg



Liquid/Gas Flow Cell

A small liquid flow cell is available with a peristaltic pump. A mylar or propylene film is pressed over the sample to maintain a thin liquid layer to minimize absorption of the x-ray beam. The same cell is often used for room temperature gas flow experiments.

Liquidcell1.jpg



Coin Cell holder

In-situ battery cycling is possible with a potentiostat that can be borrowed from the electrochemistry lab at APS. One can also be trained to load AMPIX cells in the echem lab. 34-ID-C also has an AMPIX cell holder compatible with the beamline.

Coincell1.jpg Coincell2.jpg Echemlab.png

Available Detectors (resident at the beamline)

ASI Quad (512x512) Timpix with GaAs absorber.

This detector is our daily workhorse. The structure of the GaAs needs to be divided out of the data. We have a collection of whitefield images taken at various energies. The pixels are 55 um.

ASItimepixGaAs.jpg

ASI Single (256x256) Timepix with Si sensor

The first PAD used routinely at the beamline until 2017. It's still available if a second detector is required for an experiment or the Quad fails for some reason.

ASItimepixSiSingle.jpg

Roper/PI direct detection CCD

This was our workhorse for the first decade of the beamline. It's not used primarily for recording powder rings from battery samples during cycling. 1340x1300 with 22.5 um pixels. Runs about about 1 Hz or less reading full chip. ROI can be read faster. We only use this for CXD if we need the smaller pixels and larger area than the Andor.

PIccd1.jpg

Andor direct detect CCD

Used for only a couple of years, this CCD was added to the beamline just when Timepix was being commercialized. It's actually a very good CCD with low noise and relatively flat dark field background. 1024x1024 with 13 um pixels. Can read at about 3 Hz. Roughly 60 photon pixel depth at 9 keV. If we need the small pixels this detector is a goto.

Andorccd1.jpg


Vortex EX 60

Used for x-ray fluorescence this detector has recently been calibrated and can be mounted in various positions to monitor fluorescence from a sample or measure elemental composition.

Available Detectors (Non-resident but on loan with scheduling)

Additionally, there are PADs available from the APS detector pool. Including Pilatus, Eiger, ASI Medipix3 and many others.

Publications

Our full publication list